Übersetzen...
FF38

Hardware Reconfiguration Required

ABB · ACS800 Standard Firmware

Was bedeutet FF38 ?

The inverter type (e.g., sr0025_3) has been changed, a process typically performed at the factory or during initial drive implementation. This alarm signals that the new hardware configuration needs validation by cycling the control board power.

Häufige Ursachen

  • Internal hardware components require a system reset or reconfiguration.
  • Control board detected an anomaly requiring a power cycle.
  • Firmware update or corruption requiring a hardware reset.
  • Persistent internal error state requiring a full system reinitialization.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Wait until the POWEROFF! (FF39) alarm activates, signaling readiness for the power cycle.

  2. 2

    Switch off the control board power to validate the inverter type change.

Alle Codes in diesem Handbuch durchsuchen (33)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026