Übersetzen...
7121

MOTOR STALL

ABB · ACS800

Was bedeutet 7121 ?

The motor is operating in a stall region, indicating it is unable to rotate or maintain its commanded speed due to excessive mechanical resistance or insufficient power. This fault is linked to programmable Fault Function parameters 30.10, 30.11, and 30.12.

Häufige Ursachen

  • Excessive mechanical load on the motor that exceeds its rated capacity or the drive's output capability.
  • Insufficient motor power for the application, indicating an undersized motor.
  • Mechanical binding, blockage, or friction in the driven machinery.
  • Incorrect settings for stall protection parameters (30.10 STALL FUNCTION, 30.11 STALL FREQ HI, 30.12 STALL TIME).

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the mechanical load on the motor and compare it against the drive and motor ratings. Reduce load if necessary.

  2. 2

    Inspect the driven machinery for any mechanical binding, obstructions, or excessive friction that could cause stalling.

  3. 3

    Verify Fault Function parameters 30.10 (STALL FUNCTION), 30.11 (STALL FREQ HI), and 30.12 (STALL TIME) are set appropriately for the application.

  4. 4

    Ensure the motor and ACS800 drive are correctly sized for the application's torque and power requirements.

Alle Codes in diesem Handbuch durchsuchen (33)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026