Software Overcurrent
Allen-Bradley · PowerFlex 700
Was bedeutet 36 ?
The drive output current has exceeded its 1ms current rating, which is typically 200-250% of the drive's continuous rating. This indicates a sudden, high current demand that could be due to excessive load, improper DC boost settings, or excessively high DC brake volts, risking damage to the drive.
Häufige Ursachen
- Software detected current exceeding safety limits.
- Incorrect current limiting parameter (P1-36).
- Motor drawing excessive current due to mechanical load.
- Faulty current sensing circuitry.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check for excess load on the motor.
- 2
Verify the [DC boost setting] parameter is correctly configured.
- 3
Check the [DC brake volts] parameter setting to ensure it is not too high.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026