69

DB Resistance

Allen-Bradley · PowerFlex 700

Was bedeutet 69 ?

The measured resistance of the internal Dynamic Braking (DB) resistor is outside its specified operating range. This could indicate a damaged or incorrect braking resistor, preventing effective energy dissipation during deceleration. A faulty DB resistor can lead to overvoltage trips or poor braking performance.

Häufige Ursachen

  • Braking resistor fault or excessive temperature detected.
  • Braking resistor value out of specified range.
  • Braking resistor connected improperly or shorted.
  • Excessive regenerative energy requiring braking resistor activation.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Replace the internal Dynamic Braking resistor with a specified replacement part.