No feedback voltage
Beckhoff · AX5000 Servo Drive
Was bedeutet F707 ?
This error indicates that the feedback system is not receiving the expected supply voltage, which is critical for accurate position sensing and motor control. This issue can stem from incorrect power supply wiring to the feedback system, a faulty or disconnected sense line, or the absence of a required sense connection for the specific encoder in use. The drive will be unable to operate without proper feedback voltage, leading to a standstill or uncontrolled behavior.
Häufige Ursachen
- Disconnected or damaged feedback cable (e.g., encoder or resolver cable) preventing supply voltage delivery to the sensor.
- Faulty feedback device (e.g., encoder, resolver) internally shorting the supply voltage or failing.
- Incorrectly wired feedback power supply pins at the drive or sensor connector.
- Blown fuse on the drive's internal feedback supply circuit (e.g., 5VDC or 24VDC output).
- Insufficient external power supply to the drive's feedback output (if an external supply is used and configured).
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Measure the feedback supply voltage directly at the drive's feedback connector (e.g., X10) between the VCC and GND pins (e.g., expecting 5VDC or 24VDC).
- 2
Inspect the feedback cable for cuts, crimps, or loose connections. Perform a continuity test on all conductors of the feedback cable.
- 3
Disconnect the feedback device (e.g., motor encoder) and re-measure the supply voltage at the drive's connector to rule out a short circuit in the device itself.
- 4
Check the drive's internal diagnostic LEDs or status registers (e.g., S-0-0100 for feedback status) for more specific information.
- 5
Replace the feedback cable with a known good one to eliminate cabling as a cause. If the fault persists, consider replacing the feedback device.