E8055

Motor overload, current limit active

Bosch Rexroth · IndraDrive C Drive Controllers

Was bedeutet E8055 ?

The motor is experiencing an overload condition, and its current has reached the configured limit. This indicates that the motor is being driven beyond its continuous operating capacity, posing a risk of overheating.

Häufige Ursachen

  • Excessive mechanical load on the motor.
  • Continuous operation above the motor's rated current.
  • Incorrect motor parameters in the drive's configuration.
  • Mechanical binding or obstruction in the system.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Reduce the mechanical load on the motor to within its continuous operating specifications.

  2. 2

    Verify that the motor parameters (e.g., rated current, thermal model) in the drive are correctly configured to match the motor nameplate.

  3. 3

    Inspect the mechanical system for any binding, misalignment, or excessive friction that could cause an overload.

  4. 4

    Check the application's duty cycle to ensure the motor is not continuously operating in overload conditions.