Maximum acceleration exceeded
Bosch Rexroth · IndraDrive C Drive Controllers
Was bedeutet F2039 ?
The actual acceleration or the commanded acceleration has exceeded the configured maximum limit for the axis. This can cause mechanical stress or control instability.
Häufige Ursachen
- Programmed acceleration command is higher than the drive's configured maximum acceleration limit.
- External mechanical force or uncontrolled motion causing unexpected acceleration.
- Drive parameters for maximum acceleration are set too low for the application's dynamics.
- Incorrectly tuned velocity loop or current loop causing overshoots.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the commanded acceleration value in the motion program or HMI and ensure it is within the drive's configured maximum acceleration limits.
- 2
Verify the drive parameter for maximum acceleration and adjust it if necessary, ensuring it is appropriate for the application and mechanical system.
- 3
Inspect the mechanical system for any sudden load changes or external forces that could cause unexpected acceleration.
- 4
Review the velocity and current loop tuning parameters for stability.