Fatal Error (Operation)
Bosch Rexroth · IndraDrive C Drive Controllers
Was bedeutet F8060 ?
This is a fatal error encountered during drive operation. When F8060 occurs, the closed-loop or open-loop U/f control of the drive is no longer guaranteed. The drive immediately switches off, becoming torque-free, overriding settings in P-0-0119 and P-0-0117.
Häufige Ursachen
- An unspecified error condition detected during the operational phase of the drive.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Clear the error message using command S-0-0099 (C0500 Reset class 1 diagnostics). This may require switching to parameter mode or a complete drive power cycle.
- 2
Ensure the drive is in operating mode and power is switched on ("Ab").
- 3
Switch on drive enable again (0-1 edge).
- 4
If this fatal error recurs repeatedly, replacement of an entire component (e.g. motor or drive controller) may be necessary.