Übersetzen...
F2110

Error in non-cyclical data communication of power section

Bosch Rexroth · IndraDrive MPx02

Was bedeutet F2110 ?

A fault occurred during non-cyclical data communication within the power section of the drive. This indicates an issue with data exchange that is not part of the regular control loop, potentially affecting configuration, diagnostics, or parameter updates. This can lead to improper power stage operation or failure to respond to commands.

Häufige Ursachen

  • Communication bus interference or noise
  • Defective communication hardware in the power section
  • Firmware issues affecting data exchange
  • Incorrect communication parameters
  • Temporary loss of internal communication link

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Measure and verify the control voltage supply (e.g., 24VDC) to the IndraDrive MPx02's control unit, ensuring it is stable and within specifications.

  2. 2

    Inspect all internal ribbon cables and plug-in connections between the control unit and the power module of the drive for secure seating, signs of damage, or corrosion.

  3. 3

    Verify the drive's operating parameters, particularly those related to the power section configuration and communication settings, against the machine's latest configuration backup.

  4. 4

    Measure the DC bus voltage within the drive's power section and confirm it is stable and within the specified operating range as per the drive's technical documentation.

Alle Codes in diesem Handbuch durchsuchen (99)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes