Acceleration threshold exceeded
Bosch Rexroth · IndraDrive MPx02
Was bedeutet F7014 ?
This safety technology error indicates that the actual acceleration of the motor has exceeded a safety-related acceleration threshold configured in the IndraDrive MPx02. This is a critical safety violation, implying an uncontrolled or excessively rapid change in speed, leading to an immediate safety stop.
Häufige Ursachen
- Incorrectly parameterized safety-related acceleration threshold (e.g., S-0-0092 'Maximum acceleration') for the application.
- Aggressive tuning of the speed or current control loops, causing overshoot during acceleration/deceleration.
- Mechanical shock or sudden load change causing high acceleration.
- Encoder fault or noise leading to erroneous acceleration calculation.
- Commanded acceleration exceeding the safe limit for the selected operating conditions.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Review and adjust the safety-related acceleration threshold parameters (e.g., S-0-0092) in the IndraDrive MPx02, ensuring they are appropriate for the application's safety requirements.
- 2
Check the tuning of the current and velocity control loops, specifically feed-forward and gain settings, to prevent overshoot.
- 3
Inspect the mechanical system for any sudden load changes, binding, or play that could induce high acceleration spikes.
- 4
Verify the motor encoder for accurate feedback, as noisy position data can lead to erroneous acceleration calculations.
- 5
Analyze the commanded motion profile to ensure that programmed acceleration ramps do not exceed the safety threshold.