Übersetzen...
849
Interruption of the SERCOS ring.
Bosch Rexroth · Motion Control
Was bedeutet 849 ?
The bit stream on the SERCOS ring has been interrupted, resulting in a loss of connection to the drives. This is a servo loop or drive fault, severely impacting real-time communication and control.
Häufige Ursachen
- Interruption of the bit stream on the SERCOS ring.
- Lost connection to drives on the SERCOS ring.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the integrity and connections of all glass fibers in the SERCOS ring.
- 2
Verify the operational status of all drives connected to the SERCOS ring.
- 3
Check all physical connections within the SERCOS ring.
- 4
Initiate a new SERCOS startup after rectifying physical issues.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Bosch Rexroth Motion Control