749

Serial Communication Error during Activation

Fanuc · AC Spindle Motor Alpha i-Beta i Series Parameters

Was bedeutet 749 ?

A serial communication error occurred while the Series 16i system was being activated after power-on. This indicates a problem in the communication link to the spindle amplifier, preventing normal startup.

Häufige Ursachen

  • A serial communication failure occurred during the boot-up sequence.
  • The serial device failed to respond within the expected timeout period.
  • Incorrect serial port settings (baud rate, parity, stop bits) during activation.
  • A physical connection issue with the serial cable or connector.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the serial cable connection between the controller and the device at terminal RS232-A.

  2. 2

    Confirm the serial communication parameters (baud rate, parity) match between the controller and the device.

  3. 3

    Measure the voltage levels on the serial communication lines (TXD, RXD).

  4. 4

    Attempt to establish a basic serial communication test with the device.