Was bedeutet 601 ?

This alarm is issued when the fan motor responsible for cooling the external radiator fin of the inverter has failed. This fan is a consumable part. Failure can lead to inverter overheating and potential damage if not addressed.

Häufige Ursachen

  • Fan motor for inverter radiator has failed
  • Fan clogged with foreign matter
  • Power connector of the fan is improperly connected

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check that the fan is not clogged with foreign matter

  2. 2

    Check that the power connector of the fan is connected properly

  3. 3

    Replace the fan or the entire servo amplifier module

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes