Übersetzen...
BAL

Battery alarm signal

Fanuc · i Series CNC Hardware

Was bedeutet BAL ?

This signal indicates a low battery condition for the Fanuc i Series CNC, typically affecting the SRAM or pulse coder backup. Loss of battery power can result in the loss of critical parameters, programs, and absolute position data.

Häufige Ursachen

  • Depleted or low voltage battery for memory or absolute pulse coder backup.
  • Prolonged power-off state causing the battery to discharge.
  • Poor or corroded battery connections.
  • Faulty battery holder or charging circuit (if applicable).

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Measure the battery voltage; replace the battery if it falls below the specified threshold, typically 3V for a 3.6V battery.

  2. 2

    Replace the battery with a new one of the correct type (e.g., A02B-0236-K102 or equivalent) while the Fanuc i Series CNC is powered ON to prevent data loss.

  3. 3

    Inspect battery terminals and connections for corrosion, looseness, or damage.

  4. 4

    After replacement, verify that the alarm clears and check for data integrity and correct absolute position settings if an absolute pulse coder is used.

Alle Codes in diesem Handbuch durchsuchen (6)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes