Übersetzen...
3

Over-current of Charge Current (ECM)

Fanuc · Macro B CNC Programming

Was bedeutet 3 ?

An over-current occurred in the charge current to the Energy Charge Module's (ECM) Capacitor Modules. This indicates a problem in the charging circuit, potentially due to a fault in the ECM's Control Module (A06B-6158-H010), the Capacitor Module itself, or an unstable power supply.

Häufige Ursachen

  • The charging current exceeds its maximum allowed limit.
  • Short circuit in the charging path.
  • Faulty charging components leading to high current draw.
  • Overload condition during charging cycle.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Immediately stop the machine using the emergency stop button and open the external Main Circuit Contactor (MCC) of the Power supply.

  2. 2

    Inspect the wiring of the charge circuit between the ECM Control Module and the Capacitor Modules for any short circuits or damage.

  3. 3

    Verify the integrity of the Capacitor Modules (A06B-6158-H020) for any signs of physical damage or internal short circuiting.

  4. 4

    Check the ECM Control Module (A06B-6158-H010) and DC Reactor (A06B-6158-H040) for any faults affecting the charging current regulation.

  5. 5

    Measure the input power supply to the ECM to ensure it is stable and within specified limits during charging operations.

Alle Codes in diesem Handbuch durchsuchen (26)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes