Was bedeutet 12328 ?
An attempted file operation failed because the specified file_id does not correspond to an opened file or one of the pre-defined files (CRT/KB, teach pendant, vision windows). This IO_STATUS error indicates an attempt to perform an operation on an inactive or non-existent file context. The program will abort if the file_id is invalid.
Häufige Ursachen
- Attempting to perform an operation on a file that has not been explicitly opened using a KAREL file command.
- The file_id used in the operation does not reference a currently active or valid pre-defined file.
- A previous file operation might have failed, leaving the file in an un-opened state.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify that the file corresponding to file_id has been successfully opened before attempting any subsequent read/write operations.
- 2
Ensure the file_id refers to a valid pre-defined file (e.g., CRT, KB, teach pendant window).
- 3
Use the KAREL command READ file_id(cr) to clear any existing IO_STATUS error condition.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc R-30iA R-30iB Controller