Tip Stick Detection
Fanuc · R-30iB Mate + Mate Plus Robot
Was bedeutet SRVO-076 ?
This alarm (G:i A:j) indicates that an excessive disturbance was assumed in the servo software at the start of operation, detecting an abnormal load. Possible causes include a robot collision, increased mechanical load on the axis, or issues like welding interference. This poses a risk of mechanical damage or operational halt.
Häufige Ursachen
- Failure to detect tip stick condition due to mechanical binding.
- Incorrect sensor calibration for tip position.
- Damage or misalignment of the tip detection mechanism.
- Software parameters for tip stick detection are not set correctly.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check whether the robot has collided or if the machinery load of the corresponding axis is increased.
- 2
Verify whether the load settings are valid and correctly configured in the system.
- 3
Check whether the brake of the corresponding axis is fully released.
- 4
Check whether the load weight is within the rated range for the robot; if the weight exceeds the upper limit, decrease it.
- 5
Verify whether the voltage input to the controller is within the rated voltage specifications.
- 6
Replace the servo amplifier for the affected axis.