Übersetzen...
SRVO-084
Line Tracking Pulsecoder Backup Battery Not Connected
Fanuc · R-30iB Mate + Mate Plus Robot
Was bedeutet SRVO-084 ?
This alarm occurs if the backup battery for the absolute position of the line tracking Pulsecoder has not been connected. This can lead to loss of absolute position data upon power cycle.
Häufige Ursachen
- The backup battery for the Line Tracking Pulsecoder is not connected or is depleted.
- Absence of power to the pulsecoder's internal battery circuit.
- Faulty battery connection terminal on the pulsecoder.
- Incorrect pulsecoder model installed which does not require a backup battery.
- Internal failure of the pulsecoder's battery management system.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the backup battery is correctly connected to the Line Tracking Pulsecoder.
- 2
Measure battery voltage at its terminals to confirm it is within specification.
- 3
Inspect the battery connection terminals for corrosion or damage.
- 4
Confirm the pulsecoder model is compatible with the drive's line tracking feature.
- 5
Replace the backup battery if its voltage is low or depleted.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc R-30iB Mate + Mate Plus Robot