Übersetzen...
SRVO-096

LDAL alarm (Track Encoder LED Broken)

Fanuc · R-30iB Mate + Mate Plus Robot

Was bedeutet SRVO-096 ?

This alarm (Track enc:i) indicates that the LED in the Pulsecoder (track encoder) is broken. This prevents the track encoder from generating proper position feedback, leading to loss of position control for the track. The cause and fix are identical to SRVO-074 for robot axes.

Häufige Ursachen

  • Broken or malfunctioning LED within the track encoder.
  • Optical path obstruction or dirt on the encoder disc.
  • Encoder output signal outside expected range (e.g., P4-32).
  • Damage to the encoder housing or internal components.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Replace the Pulsecoder for the affected track encoder.

  2. 2

    Remaster the robot after Pulsecoder replacement to re-establish absolute position.

Alle Codes in diesem Handbuch durchsuchen (53)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fanuc R-30iB Mate + Mate Plus Robot