SRVO-097
Pulse Not Established (Track Encoder)
Fanuc · R-30iB Mate + Mate Plus Robot
Was bedeutet SRVO-097 ?
This alarm (Enc:i) indicates that the absolute position of the Pulsecoder (track encoder) cannot be established. This typically occurs during startup or after a power cycle if the encoder's absolute position data is lost, preventing accurate track positioning. The cause and fix are identical to SRVO-075 for robot axes.
Häufige Ursachen
- Failure of the track encoder to establish initial pulse count.
- Encoder not receiving power or ground connection.
- Mechanical misalignment preventing encoder initialization.
- Parameter configuration error for encoder setup (e.g., P4-33).
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Reset the alarm condition.
- 2
Jog the affected axis (one motor revolution) until the alarm no longer occurs to re-establish the Pulsecoder's absolute position.