365

BROKEN LED(INT)

Fanuc · Series 0i-D/0i Mate-D Maintenance

Was bedeutet 365 ?

This alarm on Fanuc Series 0i-D/0i Mate-D with αi/βi Pulsecoders indicates an LED disconnection within the built-in Pulsecoder. This typically points to an internal failure of the Pulsecoder's optical components.

Häufige Ursachen

  • Internal failure of the Pulsecoder's LED component.
  • Degradation of the Pulsecoder's optical system.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Visually inspect the Pulsecoder for any external physical damage or signs of impact.

  2. 2

    Verify that the Pulsecoder cable is securely connected at both the Pulsecoder and the servo amplifier.

  3. 3

    Check the diagnostic LEDs or alarm codes on the servo amplifier for additional information.

  4. 4

    If the alarm persists after verifying connections and no external damage is visible, replace the Pulsecoder unit.