Übersetzen...
3005

Invalid Machining Start Point

Fanuc · Series 0i Manual Guide

Was bedeutet 3005 ?

This P/S alarm indicates that the machining start point defined in the program is invalid. This could be due to a coordinate outside the work envelope, an unreachable point, or a point that interferes with existing geometry, preventing the machining cycle from initiating correctly.

Häufige Ursachen

  • The programmed starting coordinates for machining are outside valid ranges.
  • Initial tool position is obstructed or in an unsafe location.
  • Invalid G-code command for initiating a machining operation.
  • Error in setting up the absolute or incremental positioning system (e.g., P2-02).

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Modify the machining program to specify a valid and reachable machining start point.

  2. 2

    Alternatively, modify the machining program to enable automatic determination of the start point by the control system.

Alle Codes in diesem Handbuch durchsuchen (25)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes