351

Serial Pulse Coder is Abnormal

Fanuc · Series 20 CNC

Was bedeutet 351 ?

Similar to Alarm 350, this alarm indicates an abnormal condition or communication error specifically related to a serial pulse coder (encoder) on the Fanuc Series 20 CNC. It signifies a problem with the digital data transfer from the encoder to the servo system.

Häufige Ursachen

  • Loose or damaged serial communication cable between the pulse coder and the servo amplifier.
  • Electrical noise interfering with the serial data transmission.
  • Malfunction of the serial pulse coder itself.
  • Faulty serial interface on the servo amplifier.
  • Incorrect parameter settings for the serial pulse coder.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the serial pulse coder cable for physical damage, loose connections, or improper shielding.

  2. 2

    Verify proper termination of the serial communication line if applicable.

  3. 3

    Check for sources of electromagnetic interference (EMI) near the cable runs and ensure proper grounding.

  4. 4

    Examine diagnostic data related to the serial pulse coder for specific error sub-codes or communication status.

  5. 5

    Temporarily swap the suspected pulse coder or servo amplifier with a known good one if feasible to isolate the fault.