Übersetzen...
A
PSM External Cooling Fin Fan Stop
Fanuc · Series 30i CNC
Was bedeutet A ?
This alarm indicates that a cooling fan associated with the external cooling fin of the Power Supply Module (PSM) has stopped. This failure impairs the module's ability to dissipate heat effectively, risking overheating of power components if not resolved promptly. It can also be triggered by internal connection issues.
Häufige Ursachen
- Cooling fan of the external cooling fin is broken or jammed.
- Poor installation of the control printed-circuit board, causing loose connectors between the control and power printed-circuit boards.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check whether the cooling fan of the external cooling fin rotates normally.
- 2
Replace the cooling fan of the external cooling fin if it is not functioning.
- 3
Ensure the control printed-circuit board is securely installed, verifying all connectors between it and the power printed-circuit board are tight.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fanuc Series 30i CNC