P

Communication Error (Amplifier and Module)

Fanuc · Series 30i CNC

Was bedeutet P ?

A communication error has occurred between the amplifier and its module. This prevents proper data exchange and control signals, which can lead to system malfunction or inability to operate the connected equipment.

Häufige Ursachen

  • Defective connector or cable (CXA2A/B) between the amplifier and module
  • Defective control printed-circuit board within the amplifier or module

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the connector and cable (CXA2A/B) for any damage, loose connections, or incorrect routing

  2. 2

    Replace the control printed-circuit board within the affected unit (amplifier or module)

  3. 3

    Replace the SVM unit if the communication error persists after checking cabling and replacing the control board

Alle Codes in diesem Handbuch durchsuchen (20)