External Temperature Sensor Defective

Fronius · Perfect Charging

Was bedeutet 13 ?

The external temperature sensor connected to the battery charger is reporting a defect or malfunction. This sensor is crucial for accurate temperature monitoring, which is essential for proper battery charging profiles and safety, preventing over- or under-temperature charging.

Häufige Ursachen

  • Physical damage to the external temperature sensor cable or the sensor probe itself.
  • Disconnection of the external temperature sensor from its designated input terminals on the charger.
  • Internal failure or degradation of the temperature sensor component.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the physical connection and wiring integrity of the external temperature sensor and its cable.

  2. 2

    Measure the resistance of the external temperature sensor across its terminals and compare it against the expected resistance curve or specified values for its temperature range.

  3. 3

    Replace the external temperature sensor if it is physically damaged or measures outside the expected resistance range.