27

Battery Not Supported

Fronius · Perfect Charging

Was bedeutet 27 ?

The connected battery's characteristics (e.g., chemistry, nominal voltage, communication protocol) are not recognized or supported by the battery charger. This prevents the charger from safely or correctly initiating a charge cycle.

Häufige Ursachen

  • Connecting a battery type (different chemistry, nominal voltage, or communication interface) that the charger is not designed to support.
  • Incorrect charger configuration for the connected battery type, or missing necessary charging profiles.
  • Missing or corrupted battery identification data (e.g., TagID) that the charger relies upon to recognize the battery.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the type and specifications of the connected battery against the charger's compatibility list or documentation.

  2. 2

    Check the charger's settings and parameters to ensure they are configured for the correct battery type, nominal voltage, and chemistry.

  3. 3

    Ensure that the battery's TagID or communication module (if present) is functioning and transmitting valid identification data to the charger.