Übersetzen...
245
Arc Detector self-test failed
Fronius · Primo GEN24 Operating Instructions
Was bedeutet 245 ?
The arc detector, a safety critical component, has failed its internal self-test. This failure indicates a malfunction of the arc detection circuitry, and the inverter will immediately disconnect itself from the grid to ensure safety.
Häufige Ursachen
- Internal malfunction or fault within the arc detector hardware.
- Corruption of the arc detector's self-test routine.
- Damaged arc detector sensor or associated electronics.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Perform an AC reset by switching the automatic circuit breaker off and then on again.
- 2
After the AC reset, the arc detector self-test will be automatically repeated. If it fails again, notify a Fronius-trained service engineer.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Fronius Primo GEN24 Operating Instructions