Polarity of DC strings reversed

Fronius · Primo GEN24 Operating Instructions

Was bedeutet 311 ?

This code indicates that the polarity of one or more DC strings connected to the inverter has been reversed. This is a critical wiring error that causes a short-term interruption in energy feeding, preventing proper operation and potentially damaging the inverter.

Häufige Ursachen

  • Incorrect wiring of the DC input from the PV modules, reversing positive and negative terminals.
  • Misconnection of PV strings during installation or maintenance.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer.

  2. 2

    Carefully check the polarity of all DC strings connected to the inverter and correct any reversed connections.

  3. 3

    Before reconnecting, verify DC string polarity using a multimeter.