Übersetzen...
407

AC module temperature sensor faulty (L2)

Fronius · Primo GEN24 Operating Instructions

Was bedeutet 407 ?

This code indicates a fault with the temperature sensor monitoring the AC module for phase L2. A faulty sensor can lead to inaccurate temperature readings, potentially causing the inverter to operate outside safe thermal limits or prevent feed-in.

Häufige Ursachen

  • Malfunction of the temperature sensor itself for L2.
  • Break in the sensor's wiring or connection to the control board.
  • Damage to the sensor due to heat or mechanical stress.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    If the status code is displayed continuously, notify a Fronius-trained service engineer for sensor inspection or replacement.

  2. 2

    Perform an AC reset to clear any transient sensor errors.

  3. 3

    Verify connections to the L2 AC module temperature sensor.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Fronius Primo GEN24 Operating Instructions