408
DC component measured in the grid too high
Fronius · Primo GEN24 Operating Instructions
Was bedeutet 408 ?
This code indicates that an excessively high DC current component has been measured in the AC grid. Such a condition can indicate a fault within the inverter's power conversion stages or an external grid disturbance, typically causing the inverter to disconnect for safety.
Häufige Ursachen
- Internal fault within the inverter causing DC current injection into the AC grid.
- Malfunction of grid monitoring relays or sensors detecting DC components.
- Fault in the inverter's output filter or control.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
If the status code is displayed continuously, notify a Fronius-trained service engineer for diagnosis and repair.
- 2
Perform an AC reset to cycle the inverter and clear transient measurement errors.
- 3
Verify grid connection integrity and absence of external DC injection sources.