452
Communication error between the processors
Fronius · Primo GEN24 Operating Instructions
Was bedeutet 452 ?
This code indicates a communication error between the inverter's internal processors. This is a critical internal fault that prevents the control system from functioning correctly and will halt energy feeding.
Häufige Ursachen
- Faulty internal communication bus or interface between processors.
- Malfunction of one or more internal processors.
- Electromagnetic interference affecting sensitive communication lines.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
If the status code is displayed continuously, notify a Fronius-trained service engineer for internal diagnosis and repair.
- 2
Perform an AC reset by cycling the automatic circuit breaker to attempt to re-establish inter-processor communication.
- 3
Check for stable power supplies to all internal processors.