Übersetzen...
303

DC module overtemperature

Fronius · Symo Advanced Manual

Was bedeutet 303 ?

The DC power module within the inverter has exceeded its safe operating temperature. This triggers a short-term interruption in energy feeding, and the inverter will then attempt to resume operation once the temperature drops.

Häufige Ursachen

  • Restricted airflow to the inverter's cooling elements
  • Accumulation of dust or debris on cooling air openings or heat sink
  • High ambient temperature exceeding inverter specifications

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Purge the cooling air openings and heat sink to ensure proper airflow.

  2. 2

    If this status code keeps recurring after cleaning, contact your system engineer for further inspection.

Alle Codes in diesem Handbuch durchsuchen (60)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026