Übersetzen...
13582 E013

N0 status test to inactive

Heidenhain · NC Control

Was bedeutet 13582 E013 ?

The CCU shut-off signal '-N0' fails to switch to a high level, and its measured status is at a 'low' level. This indicates a potential software error or a hardware defect.

Häufige Ursachen

  • CCU shut-off signal: -N0 does not switch to high level.
  • The measured status of the "-N0" signal is "low" level.
  • Software error.
  • Hardware defective.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Power cycle the NC control to attempt a reset of the safety circuit and signal states.

  2. 2

    Check the wiring and connections related to the -N0 signal path for any damage, loose terminals, or improper shielding.

  3. 3

    Inspect the controller board (CCU) for any visible damage, burnt components, or signs of hardware malfunction.

  4. 4

    Verify the safety software configuration and parameters related to the -N0 signal's inactive state and its expected behavior.

  5. 5

    If available, use a multimeter or oscilloscope to monitor the -N0 signal level and confirm it remains low when expected to transition to high.

Alle Codes in diesem Handbuch durchsuchen (58)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes