Status NR1/NR2 not equal
Heidenhain · NC Control
Was bedeutet 2928 E001 ?
The status of NR1 and NR2 inputs is not equal, likely due to incorrect connection of the NR2 input or an internal software error. This indicates a discrepancy in critical safety or feedback signals.
Häufige Ursachen
- NR2 input incorrectly connected.
- Internal software error.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the wiring of the NR1 and NR2 inputs for the affected component, ensuring NR2 is connected correctly according to the machine's electrical schematics.
- 2
Inspect the physical connections for looseness, damage, or improper termination at the input terminals.
- 3
Verify the software version of the NC control for any known issues or specific requirements related to NR1/NR2 input handling.
- 4
Perform continuity checks on the NR1/NR2 signal lines and their corresponding safety module or input card to ensure signal integrity.