Error in CC switch-off test
Heidenhain · NC Control
Was bedeutet 5646 E013 ?
During a CC switch-off test, the CC switch-off signal '-N0' failed to switch to a high (inactive) level. This indicates a hardware defect on the controller board.
Häufige Ursachen
- CC switch-off signal: -N0 does not switch to high level.
- Hardware defective.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Power cycle the NC control to attempt a reset of the safety circuit and signal states, then re-attempt the CC switch-off test.
- 2
Check the wiring and connections related to the -N0 signal path on the controller board for any damage, loose terminals, or corrosion.
- 3
Inspect the controller board for any visible damage, burnt components, or signs of malfunction.
- 4
If available, use a multimeter or oscilloscope to monitor the -N0 signal level during the switch-off test to confirm if it remains low when expected to go high.