Übersetzen...
7949 A043

CC%d BA2 only one axis allowed

Heidenhain · NC Control

Was bedeutet 7949 A043 ?

In operating mode BA2 with open safety doors, the simultaneous movement of more than one axis is not allowed. This error is triggered when this safety rule is violated.

Häufige Ursachen

  • Simultaneous movement of more than one axis detected in operating mode BA2 with open safety doors.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Ensure all axes are at a complete standstill before attempting any movement in BA2 operating mode with open safety doors.

  2. 2

    Confirm that only one axis is commanded to move at a time when operating in BA2 mode with safety doors open.

  3. 3

    Verify the functionality and correct operation of the safety door interlocks to ensure their status is accurately detected by the NC control.

  4. 4

    Review the NC program or manual jogging procedures to ensure strict adherence to the single-axis movement rule in this specific operating mode.

Alle Codes in diesem Handbuch durchsuchen (58)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes