2039
Output overcurrent
Huawei · SUN2000-(3KTL-10KTL)-M1 Solar Inverter
Was bedeutet 2039 ?
The SUN2000's transient output current exceeds its upper threshold, triggering protection due to a dramatic drop in power grid voltage or a short-circuited power grid. This indicates an external electrical fault affecting the inverter's output.
Häufige Ursachen
- The power grid voltage drops dramatically.
- The power grid is short-circuited.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Observe if the SUN2000 automatically recovers after the fault is rectified, as it monitors external operating conditions in real time.
- 2
If the alarm persists and affects energy yield, check whether the output is short-circuited.