DC Over Voltage
Huawei · SUN2000 8-28KTL Solar Inverter
Was bedeutet 103 ?
A major fault caused by excessive PV string output voltage, where the open-circuit voltage of the PV string exceeds the maximum operating voltage of the SUN2000. This can damage the inverter's DC input stage and prevents power generation.
Häufige Ursachen
- Too many PV modules connected in series, resulting in the PV string open-circuit voltage being greater than the maximum operating voltage of the SUN2000.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the number of PV modules connected in series for the affected string.
- 2
Reduce the number of PV modules connected in series until the PV string output voltage drops to the specified operating range for the SUN2000.