Invalid addressing of MDT-data container A
Indramat · CLM01.3-M Flying Cutoff Control
Was bedeutet E408 ?
This warning from the Indramat DIAX04 SSE-03VRS indicates an error during the index check in the multiplex channel. During cyclical data exchange, the index used to access the S-0-0370 (Configuration list for MDT data container) points to a non-initialized field in the list, preventing proper data access.
Häufige Ursachen
- The index for accessing the S-0-0370 list is incorrectly calculated or provided by the control system.
- The S-0-0370, Configuration list for MDT data container has not been properly initialized or configured.
- Corruption of data within the multiplex channel or the S-0-0370 list.
- Timing issues in cyclical data exchange leading to invalid index reads.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify the programming of the control system that generates the index for accessing the S-0-0370 list, ensuring it points to valid, initialized fields.
- 2
Check the configuration and initialization of the S-0-0370, Configuration list for MDT data container parameter in the Indramat DIAX04 SSE-03VRS, ensuring all necessary fields are properly defined.
- 3
Re-initialize the drive configuration or relevant parameters to ensure the MDT data container list is correctly set up.
- 4
Review the cyclical data exchange timing and synchronization between the controller and drive to rule out timing-related issues.