Übersetzen...
S-0-0011 Bit 12

Communication Error

Indramat · dds 2.1 digital servo drive User Manual

Was bedeutet S-0-0011 Bit 12 ?

A Class 1 Diagnostic indicating a critical failure in the SERCOS communication between the master controller and the DDS 2.1 drive. This error can manifest as various issues like MST/MDT failures, invalid communication phase transitions, or address conflicts, leading to a drive shutdown. The drive decelerates to zero speed and shuts down torque. This condition is reset only after the cause is cleared and the command 'Reset Class 1 Diagnostics' is received via the service channel.

Häufige Ursachen

  • Break or damage in the SERCOS fiber optic cable or connector between the master and DDS 2.1.
  • Incorrect SERCOS ring configuration, including incorrect drive addressing (e.g., two drives with the same address).
  • Failure of the SERCOS interface module in the DDS 2.1 drive or the master controller.
  • Timing parameter mismatches in the SERCOS configuration (e.g., S-0-0001 Control Unit Cycle Time, S-0-0002 SERCOS Cycle Time).
  • Invalid communication phase transitions or a master control word not correctly commanding phase changes.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the SERCOS fiber optic cables and connectors for damage, cleanliness, and secure connections.

  2. 2

    Verify the SERCOS ring topology and ensure each DDS 2.1 drive has a unique and correct address.

  3. 3

    Check the diagnostic indicators on both the master controller and the DDS 2.1 for specific SERCOS status information.

  4. 4

    Review and confirm all SERCOS timing parameters (e.g., S-0-0001, S-0-0002, S-0-0003 Minimum AT Transmit Starting Time) are correctly configured in both the master and slave devices.

  5. 5

    Command a 'Reset Class 1 Diagnostics' via the service channel after verifying physical connections and parameters.

Alle Codes in diesem Handbuch durchsuchen (19)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Indramat dds 2.1 digital servo drive User Manual