02

Invalid Input

Indramat · ServoDyn D Servo Drive

Was bedeutet 02 ?

This error occurs when an invalid value is stored in a CLM01.3-M parameter, exceeding its defined minimum or maximum limits. The invalid data is typically indicated by an asterisk (*) on the display, and the error message appears on the first line.

Häufige Ursachen

  • Parameter value entered is outside the specified minimum or maximum limits for that parameter.
  • Incorrect data type or format (e.g., non-numeric) was entered for a parameter.
  • Typographical error during manual parameter entry via the keypad.
  • Automated parameter upload from an external device contained erroneous data.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Identify the specific parameter indicated on the CLM01.3-M display that is showing an invalid input (e.g., with an asterisk).

  2. 2

    Switch the CLM01.3-M to Parameter mode, navigate to the affected parameter, and press the CL (Clear) key to remove the invalid data.

  3. 3

    Consult Chapter 4 of the manual to verify the correct minimum, maximum, and format requirements for the identified parameter.

  4. 4

    Re-enter the correct parameter value, ensuring it adheres to all specified limits and data types.

  5. 5

    If the error re-occurs, verify that the entry keypad or any external input device is functioning correctly and not sending corrupted data.