61
Overspeed
Kone · CMXC-022 Frequency Control Upgrade Kit
Was bedeutet 61 ?
An overspeed condition has been detected by the R&M Materials Handling Frequency Converter, or there is interference affecting the speed signal from the encoder connected to ENC1A. This can lead to uncontrolled motor speed, posing a safety risk if not corrected.
Häufige Ursachen
- Motor overspeed detected
- Interference in the speed signal connected to ENC1A
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check the supply voltage
- 2
Verify the load measurement operation and calibration
- 3
Check the sensor cable grounding and inverter PE- connections
- 4
Check or replace the speed sensor connected to ENC1A