63
Stall
Kone · CMXC-022 Frequency Control Upgrade Kit
Was bedeutet 63 ?
The motor is not running, indicating a stall condition detected by the R&M Materials Handling Frequency Converter. This can be due to a mechanical failure in the gear system or a missing speed signal from the encoder connected to ENC1A, preventing the drive from detecting motor movement.
Häufige Ursachen
- Motor not running (stall condition)
- Mechanical failure, e.g., in the gear system
- Missing speed signal in ENC1A
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check or replace the motor
- 2
Check and repair the motor wiring
- 3
Check hoist operation without any load applied
- 4
Check or replace the speed sensor connected to ENC1A