Übersetzen...
71
Brake control
Kone · CMXC-022 Frequency Control Upgrade Kit
Was bedeutet 71 ?
An error has been detected within the brake control circuit of the R&M Materials Handling Frequency Converter, indicating a malfunction that could prevent the brake from engaging or disengaging properly. This poses a significant safety risk, especially in hoist applications.
Häufige Ursachen
- Error detected in the brake control circuit
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Check and repair the brake control circuit wiring
- 2
Measure the brake coil resistance and compare to specifications
- 3
Replace the brake if its resistance is outside specifications
- 4
If the problem recurs, replace the inverter
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Kone CMXC-022 Frequency Control Upgrade Kit