Kone · CMXC-022 Frequency Control Upgrade Kit

Was bedeutet 93 ?

A Controlled Common Use (CCU) activation has occurred, meaning another device connected to the CAN bus initiated the stopping of the R&M Materials Handling Frequency Converter system. This indicates an external device commanding a stop via the shared network.

Häufige Ursachen

  • Another device connected to the CAN bus has caused the system to stop

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify the operational status and control logic of other devices connected to the CAN bus to identify which device is initiating the CCU stop command.

  2. 2

    Inspect the CAN bus wiring and connections (e.g., termination resistors, shielding) for damage, loose connections, or incorrect configuration.

  3. 3

    Verify the frequency converter's communication parameters (e.g., CAN bus address, baud rate, control source selection) are correctly configured according to the system's design documentation.

  4. 4

    Check the status of any external safety circuits or control logic (e.g., emergency stops, interlocks) that are configured to issue a stop command via the CAN bus.