Übersetzen...
BATT (Failure)

Battery Failure

Kone · Electric Traction Elevators

Was bedeutet BATT (Failure) ?

The backup battery for the phone board has failed, indicated by the BATT LED being ON (Red). This critical fault signifies that the battery needs replacement or its fuse has blown, compromising the system's ability to operate during main power outages.

Häufige Ursachen

  • The backup battery has reached its end of service life and can no longer hold an adequate charge.
  • The battery fuse on the phone board is open, preventing current flow to or from the battery.
  • Internal failure within the battery pack, such as a shorted cell, has occurred.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Check the battery fuse located on the phone board; verify its continuity with a multimeter and replace if blown.

  2. 2

    Measure the voltage of the backup battery at its terminals; if significantly below nominal voltage or if it fails a load test, replace the battery.

  3. 3

    Inspect the battery charging circuit on the phone board by measuring charging current/voltage at the battery terminals when main power is present.

Alle Codes in diesem Handbuch durchsuchen (13)
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026

Verwandte Fehlercodes

Quelle: Kone Electric Traction Elevators