Übersetzen...
105
BMS Alarm
Kone · Elevator Control
Was bedeutet 105 ?
An alarm has been triggered by the Battery Management System (BMS), indicating a non-critical issue with the battery. This condition limits the drive speed.
Häufige Ursachen
- BMS detecting a minor anomaly related to battery health, temperature, or cell imbalance.
- Battery parameters nearing their limits (e.g., charge/discharge temperature, voltage).
- Intermittent communication issue with the BMS.
Reparaturschritte & Checkliste
Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.
- 1
Verify battery terminal voltage against specified nominal values under both no-load and charge conditions.
- 2
Inspect all battery power and communication cabling for loose connections, corrosion, or physical damage.
- 3
Measure the charging voltage and current delivered to the battery by the integrated charging unit.
- 4
Check the elevator control unit's diagnostic log for detailed BMS sub-faults or specific battery status readings.
Verifizierte technische Daten. Zuletzt aktualisiert: March 2026
Verwandte Fehlercodes
Quelle: Kone Elevator Control