1060

CAPACITOR CHARGE

Kone · Elevator Control

Was bedeutet 1060 ?

The motor controller (codes 1060, 2060, 3060) has detected an issue with the capacitor charge process. This typically relates to the DC bus charging circuit during power-up. The specific lift reaction is controller dependent.

Häufige Ursachen

  • Failure of pre-charge circuit components (e.g., resistor, relay).
  • Excessive resistance in the DC link charging path.
  • Faulty DC bus capacitors or voltage measurement circuit.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Verify incoming AC supply voltage at the motor controller's input terminals against nominal values.

  2. 2

    Inspect all power cabling and connections to the motor controller for looseness, corrosion, or damage, focusing on the main power input and DC bus pre-charge circuit components.

  3. 3

    Measure the DC bus voltage across the appropriate terminals on the motor controller during a power-up attempt to observe the charging process.

  4. 4

    Check the operation and auxiliary contacts of any pre-charge contactors or relays associated with the DC bus charging circuit.

  5. 5

    Verify the motor controller's drive parameters related to power-up, DC bus pre-charge, and undervoltage thresholds against the manufacturer's specifications.