18

Pothole Guard Fault

Kone · Elevator Control

Was bedeutet 18 ?

A fault has been detected in the pothole guard system, compromising its ability to operate correctly. This fault disables both lifting and driving functions for safety.

Häufige Ursachen

  • Pothole guard sensor malfunction or system failure.
  • Pothole guard circuit open or shorted.
  • Mechanical damage preventing pothole guard deployment or retraction.

Reparaturschritte & Checkliste

Klicken Sie auf Schritte, um Ihren Fortschritt zu verfolgen.

  1. 1

    Inspect the pothole guard mechanism for physical obstructions, damage, or excessive wear that might prevent its free movement or proper deployment/retraction.

  2. 2

    Check all electrical wiring and connections to the pothole guard sensors and actuators for looseness, damage, or corrosion.

  3. 3

    Verify the status of the pothole guard position sensors via the Kone Kone Elevator Control's diagnostic interface or I/O status screen, confirming their accurate state.

  4. 4

    Measure the supply voltage at the pothole guard actuator terminals to ensure it matches the specified nominal voltage according to the wiring diagrams.